Detection of fresh-water/sea-water interface by the time domain electromagnetic (TDEM) method in Israel
Goldman, M.; Arad, A.; Kafri, U.; Gilad, D.; Melloul, A. (1989). Detection of fresh-water/sea-water interface by the time domain electromagnetic (TDEM) method in Israel. Natuurwet. Tijdschr. 70(1-4): 329-344
In: Natuurwetenschappelijk Tijdschrift. L. Walschot/Natuur- en Geneeskundige Vennootschap: Gent. ISSN 0770-1748, more
Also appears in:
De Breuck, W.; Walschot, L. (Ed.) (1989). Proceedings of the 10th Salt-Water Intrusion Meeting Ghent (Belgium), 16-20 May 1988. Natuurwetenschappelijk Tijdschrift, 70(1-4). Natuurwetenschappelijk Tijdschrift: Gent. 408 pp., more
A feasibility study on the applicability of the TDEM method in detecting sea-water intrusion into fresh-water aquifers was carried out. It was found that absolute resistivity values varying between 0,5-1,5 ohm-m are typical for sea-water intrusion. These are different from any other resistivity values which stem from other known lithology and/or water-salinity combinations. The TDEM method has proved to be a reasonable accurate technique for detection of fresh-water/sea-water interface in carbonate, and particularly, coastal aquifers.
All data in the Integrated Marine Information System (IMIS) is subject to the VLIZ privacy policy